Heating insert SD 6 F

Our smallest and narrowest.
The SD 6 F heating insert is characterized by its low installation depth of only 45 cm. Ventilation for convective heat is integrated in the front panel. Heating with wood or brown coal? Since the end of 2016, the SD 6 F has now also been approved for mixed firing. So you can change the fuel type quickly and easily.

Front panel: 420 x 820 mm
body: 330 x 700 x 450 mm
Type: Door hinge on the right, self-closing, not changeable
Wood performance: 6 kW
Performance of brown coal briquettes: 4 kW

Standard

doorstop
right-wing

Double
glazing

mixed fire

1. BImSchV
Level 2

Energy-
efficiency-
Class
to (EU)
2015/1186

Multiple glazing

The multiple glazing ensures approx. 30% less heat emission via the glass pane, higher combustion chamber temperatures and clean panes over a longer period of time.

inner lining

Our heating inserts are equipped with solid fireclay bricks which are placed in the device dry, without walling in.

stove body

The furnace body consists of high-temperature resistant furnace casting. This material has proven itself over decades.

Technical data

  Wood Lignite briquettes (BKB)
Nominal heat output including NHK 6 kW 4 kW
Output range 3,7-6,4 kW
Efficiency > 80% > 80%
Insulation thickness (if the wall is not to be protected) (based on SILCA® 250KM) 60 mm 60 mm
Combustion air inlet
Max. firewood length ? cm ? cm
Weight including chamotte 150 kg 150 kg
Heat emission: through the lens 10 % 10 %
Heat emission: convective power 90 % 90 %

Data for chimney sweep according to DIN EN 13384 (closed)

Triple of values ​​at NWL
  Wood Lignite briquettes (BKB)
Exhaust gas mass flow 6,9 g / s 4,9 g / s
Exhaust gas temperature behind the additional button 149 ° C 105 ° C
required delivery pressure 12 Pa 12 Pa
Triplet of values ​​for the calculation of the ceramic trains (fuel: wood)
  Wood Lignite briquettes (BKB)
firing 11,2 kW
Exhaust gas mass flow 14,0 g / s
Exhaust gas temperature before the post button 504 ° C
required delivery pressure 15 Pa
Combustion air requirement 31,9 m³ / h